Loop Verification (models 2W-B and 2WT-B only) Consult NFPA 72, the local Authority Having Jurisdiction (AHJ), and/or applicable codes for specific information regarding the spacing and placement of smoke detectors. Any 2-wire i3 smoke detector (2W-B, 2WT-B, 2WTA-B, or 2WTRB) wired In wet or excessively humid areas, or next to bathrooms with showers. Do NOT Install Detectors in the Following Areas: In or near areas where particles of combustion are normally present such as kitchens; in garages (vehicle exhaust); near furnaces, hot water heaters, or gas space heaters. - 2W- B More results Similar Description - 2W-B More results endstream
endobj
473 0 obj
<>
endobj
474 0 obj
<>
endobj
475 0 obj
<>
endobj
476 0 obj
<>
endobj
477 0 obj
<>
endobj
478 0 obj
<>stream
NOTE: To install units so that corresponding LEDs are lined up, refer to the However, the i3 Series smoke detector allows for fast and easy inspection. system or the conduit, both LEDs will blink for up to 4 minutes before displaying detector status (see Table 2). 4. Subscirbe to specific System Sensor email communications. This device complies with part 15 of the FCC Rules. tor. 2W-B - System Sensor - JMAC We're here to provide technical support for System Sensor products and service. 30 % peak to peak of applied voltage Our hardwired CO detectors with RealTest use electrochemical sensors to measure carbon monoxide levels and alert residents with a flashing Temp-4 signal alarm. To engage the tamper-resistant feature, cut the small plastic tab located on the mounting base (Figure 2), and then install the detector. System Sensor is pleased to provide this Strobe Coverage Calculator, formerly known as Equivalent Facilitation Calculator. 2-Wire i3 Detector Wired in Style D Configuration: B. I was planning on installing about 11 of these on a vista 21ip panel, what is the power draw I should account for when planning against the 650 mA allowance for the panel? 50 A average mounted: Proper wire gauges should be used. 2.0 inches User manual System Sensor 2WTA-B (English - 4 pages) Figure 3b: Wiring Diagram, 4W-B and 4WT-B 6.3 oz. photoelectric smoke detector (4 pages), Intrinsically-safe plug-in intelligent photoelectronic smoke detector (6 pages), Single-ended reflected type projected beam smoke detector (19 pages), Single-ended reflected type projected beam smoke detector (14 pages), Air duct smoke detector with extended air speed range (8 pages), Photoelectronic smoke detector with fixed heat and integral temp-3 sounder (4 pages), Reflected type projected beam smoke detector (6 pages), Combination carbon
6. To a 312-inch or 4-inch octagonal box, or NOTE: T A. to the plastic. reasonable protection against harmful interference in a residential installation. Test each detector as described in Testing. In or near areas where particles of combustion are normally present A, System Sensor i3 series 2w-b, 2wt-b, 4w-b, 4wt-b Data Sheet. Should Peak Standby Current: heaters, or gas space heaters. Three-Year Limited Warranty Series detectors are designed to provide open area protec-, tion. Place control panel or module in EZ Walk Test mode (refer to panel manufacturers manual or 2W-MOD manual D500-46-00). from the end of the feed wire, inserting it into the proper base terminal, and The System Sensor 2WTA-B is a 2-wire smoke and fixed heat sensor with a built-in sounder. in the Style D initiating device circuit (IDC) configuration requires the use D100-96-00. 2W-B - SYSTEM SENSOR - i3 Series Detector, | Anixter Remove the detector cover by turning counterclockwise. It should be straightforward if you do not need to wire the back plate. Notify the proper authorities when the system is back in service. Gray. Just fill out the form and click your area of interest. For two-wire models 2W-B and 2WT-B, connect detectors only to compatible alarm control panels as identified by System Sensor's compatibility chart. The 2W -MOD2 can. I am very happy with the purchase and while I only needed one I bought 2 to have one in reserve. I see other smoke detectors that claim a lifespan of 10 years and recommend replacement at that time. Do NOT Install Detectors in the Following Areas: For two-wire models 2W-B and 2WT-B, connect detectors only to compatible alarm control panels as identified by System Sensor's compatibility chart. Hey, guys. At a minimum, cleaning, Models 2W-B and 2WT-B are 2-wire photoelectric smoke detec-, tors; models 4W-B and 4WT-B are 4-wire photoelectric smoke, detectors. 3825 Ohio Avenue
Vacuum or use canned air to remove any dust or particles that are present on both chamber halves. However, you can also use the 2W-B smoke detector with other alarm control panels, but you should verify compatibility with the manufacturer of the alarm control panel first. Hold a smoldering punk stick or cotton wick at the side of the detector and (if excessive electrical noise is present) Products - Honeywell Explore System Sensor like white papers, announcements, technical bulletins, case studies, and more. And today we're going to be adding two-wire smokes to our DSC Neo system. System connected smoke detectors may be successfully deployed for many years, and no scheduled end of life replacement is prescribed. To engage the tamper-resistant feature, cut the small plastic tab located on the mounting base (Figure No agent, representative, dealer, or employee of the Company has the authority to Amazon.com: System Sensor 2wb Testing for System Smoke Detectors, which provides detailed information on detector Air conditioners, heaters, fans, and fresh air intakes and returns can drive smoke away from the detector. However zones 1 and 2 can support 16 on each zone. System Sensor 2W-B Product Description: The System Sensor 2W-B is a i3-Series conventional, two-wire, photoelectric smoke detector. The drop-in ceiling tile speakers, strobes and speaker strobes offer a complete turn-key solution that offers a cleaner and faster installation, reduced labor costs and lower risk than traditional AV notification appliances. The mounting base installation is When the detector is in the alarm mode, the red LED latches on. We're here to help with any issues or questions. When performing maintenance on your smoke detector, simply turn the 2W-B head counter clockwise to remove it from the base. Using a 1000-1500 watt hair dryer, direct the heat toward either of the thermistors. 4.Direct mount or to ceiling using drywall fasteners (Figure 2). B101B / B107B A 120 View a list of all System Sensor locations worldwide. Remove the top half of the screen/sensing chamber by lifting straight up 20 mA 12 Volt Systems COVER. InnovairFlex duct smoke detectors combine an impressive collection of innovations to greatly simplify HVAC system monitoring. I have a Vista 6150 15P Control Panel and an old System Sensor 2312/24TB 4 wire Smoke/heat detector. Tools & Software | System Sensor | Honeywell NIB!! We're here to help with any issues or questions. :9M9yB*]}8s5CC)^.+Jnz>>;?88^]~xxfntMr}->rz_Sxu%fYz,b,v%-]r9Yfl){fy\1W+ye"3#r9c/DfO+"!a4{=ff^,. It will take approximately 80. seconds for the detector to finish the power-up cycle (see Table 2). Make sure to observe polarity when wiring up your smoke detectors and you should connect an end-of-line resistor across the loop wires at the last 2W-B on your loop. haha, Hi Dustin, ANSI/UL 1971 does not provide ratings for each angle based on actual test results.". Near fresh air inlets or returns or excessively drafty areas. This latest software also includes an enhanced interface for increased ease of use. 2WTA-B - System Sensor - JMAC current list of detectors and UL Listed compatible control units. Dimensions: 2.0" (51mm) H x 5.3" (127mm) Dia. An overview of latest updates, essential resources, and webinars. This chart contains the current list of detectors and UL Listed compatible control units. Start-up Capacitance: Product specifications subject to change without notice. When mounting the i3 Series, ensure that the head is mounted to the correct base. for the detector to stabilize before testing. Series 2W-MOD module (refer to installation manual D500-46-00), the 2W-B and 2WT-B are capable of generating a "maintenance. We offer conventional and intelligent products for smoke detection, heat detection, fire and CO combination detection, and multi-criteria / multi-sensor detection, as well as bases and accessories. Each zone provides enough stand by current (2ma) to power up to sixteen smoke detectors. PipeIQ guides users through the initial pipe layout and system configuration for a FAAST aspiration system. No Contract Alarm Monitoring starting at $10 a month! General Description 2. the latest products, and offers. 1015 0 obj
<>/Encrypt 1001 0 R/Filter/FlateDecode/ID[<493E40FFCF1D3F747B74E48D03207C10>]/Index[1000 51]/Info 999 0 R/Length 93/Prev 198552/Root 1002 0 R/Size 1051/Type/XRef/W[1 3 1]>>stream
Ripple Voltage: Start-up Time: A copy of this list is available from System Sensor upon request. A copy of this In order for this feature to work properly, the chamber must never be opened while power is applied to the smoke detector. Therefore, System Sensor recommends : System Sensor 2W-B - 2-Wire Smoke Detector - Alarm Grid The microprocessor, allows the detector to automatically adjust its sensitivity back, to the factory setting when it becomes more sensitive due to, contaminants settling in its chamber. any latin characters (a-z, A-Z) any numbers (0-9) special characters ("-", "_" and ". Please read thoroughly System Sensor manual A05-1003, Applications Guide N/A N/A 120 System Sensor 2851B A Photo B101B / B107B A 120 System Sensor 2851BTH A Photo / Therm. Have feedback about a particular System Sensor product? further simplified by the incorporation of features compatible with drywall Physical Specifications Heat Sensor (Model 2WT-B and 4WT-B): 0.5 Amp @ 30 V AC/DC applicable state and local codes, and any special requirements of the local Fire Alarm Systems | System Sensor L-series indoor horn/strobes System Sensor L-series indoor horn/ strobes www.boschsecurity.com u u Plug-in design with minimal intrusion into the back box u Field-selectable candela settings of 15 or 30 cd at 12 V or 15, 30, 75, 95, 110, 135, and 185 cd at 24 V u Horn rated at 88+ dBA at 16 V Rotary switch for horn tone and two volume settings Explore System Sensor products including: AV Notification, Beam Smoke detection, CO detection, HVAC Smoke detection, spot smoke detection, relays, & modules. 4.3 (21) $6371. System Sensor 2WTA-B I3 Series 4-Wire Conventional Photoelectric and 135F Fixed Temperature Thermal Detector with Built-in Sounder, 85 dB Sounder, Form C Relay, Isolated Thermal Sensor. performed and the system will be temporarily out of service. Figure 1: Mounting of Detector. Replace the top half of the screen/sensing chamber by aligning the arrow If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to To view our listings, please visit one of the following sites. I am wondering if there is too much power connected to the panel for the sirens to sound. To measure the detectors sensitivity, the i3 Series Model SENS-RDR Infrared Certain System Sensor SWIFT AV bases have the potential to generate a premature and erroneous low battery notification. System Sensor's product 2-wire compatibility listings are available onlinefor you to view and print out. Operating Temperature Range: Please refer to insert for the Limitations of Fire Alarm Systems The CLSS Tool Suite allows you to perform battery, voltage drop, and Db line loss calculations in a single desktop application. There is a red and green LED on the head of the 2W-B smoke detector. Multi-voltage conventional relays are used for high-current switching applications, such as fan and damper assembly control, door control, air handling unit controls, and other building system interfaces. General CLSS Tool Suite Discontinued Product Finder AV Audio Samples: AV Tones Calculator: AV Strobe Coverage Calculator: Voltage Drop Calculator: Sound Pressure Loss Table 2: Power-up Sequence for LED Status Indication*, (if excessive electrical noise is present). Activate the light at the display. System Sensor shall have no liability. This Warranty gives you specific legal rights, and you w responsible for an unreported house fire. 5.3 inches System Sensor 2W-B Installation And Maintenance Instructions - ManualsLib To stay in the know on upcoming news and announcements, subscribe. The i3 Series detectors include a tamper-resistant feature that prevents removal into the test PDF INSTALLATION AND MAINTENANCE INSTRUCTIONS Series - National Training Center It can connect with a Honeywell VISTA System at Zone 1. 15 sec Copies of this manual are available, NOTICE: This manual shall be left with the owner/user of this, IMPORTANT: This detector must be tested and maintained regu-, larly following NFPA 72 requirements. the incorporation of features compatible with drywall fasteners. Freeze Trouble (Model 2WT-B and 4WT-B): Maximum Initial Amazon.com: System Sensor 2w-b it become necessary, the screen/sensing chamber is field replaceable. No Contract Alarm Monitoring starting at $10 a month! This equipment generates, uses and can radiate radio frequency energy and, if not installed and used of a 2W-MOD2 module. System Sensors intelligent and conventional modules are designed to help you meet a wide range of application requirements. switch opening; push and hold. System Sensor web site at www.systemsensor.com. NOTICE: This manual shall be left with the owner/user of this equipment. KingOfTheP4s 3 yr. ago Best thing to do in this case would be to call the company of your choice, such as EST, and ask a sales representative to give you a list of MRI-safe devices. Enter your email address and check your inbox. All wiring must be installed in compliance with the National Electrical Code, applicable state and local codes, and any special requirements of the local Authority Having Jurisdiction. Unfortunately we do not support fire panels like the 32FB. Detectors must be tested after installation and following maintenance. NIB!! Turn on: 1. 41F (5C) I am very happy with the purchase and while I only needed one I bought 2 to have one in reserve. It sounds like you may be experiencing a low battery issue possibly. In dusty, dirty, or insect-infested areas. I recommend powering down the system and placing your system on test mode if monitored before swapping in the new smoke. The mounting base installation is further simplified by. Voltage Drop calculations for System Sensor AV products can be done using the Honeywell Online Tools for Fire (HOTFire) site. Wire connections are made by stripping approximately 14-inch of insulation from the end of the feed wire, inserting it into the proper base terminal, and tightening the screw to secure the wire in place. Heat Sensor (Model 2WT-B and 4WT-B): 135F (57.2C) Freeze Trouble (Model 2WT-B and 4WT-B): 41F (5C) Operating Temperature Range: 2W-B and 4W-B: 32 to 120F (0 to 49C) 2WT-B and 4WT-B: 32 to 100F (0 to 37.8C) Operating Humidity Range: 0 to 95% RH non-condensing Storage Temperature Range: -4 to 158F (-20 to 70C) Diameter (including base): r^ lC-kr$EG_ KD/T=[ $y`j"lOmX LX6F(F;x*+yj#xgUB?fH"U*zN84Vz
D~m$y:67HqwZJ:RSYk4MU=';W(pg|s[pJTW/X
'@GWSYm
}Fs When the sensing chamber gets too dirty and the 2W-B is no longer calibrated to the proper sensitivity, the smoke detector will alert you with a red LED that blinks every five seconds so that you can perform the necessary maintenance. condition if the temperature is below 41F. unreasonable use, modifications, or alterations occurring after the date of manufacture. In very cold or very hot areas. Ep. A couple of things to note before NOTE: Style. item 2 System Sensor 2W-B I3 Series 2-Wire Photoelectric Smoke Detector, item 3 NEW System Sensor 2W-B 2WB i3 Series 2-Wire Photoelectric Smoke Detector Fire, item 4 System Sensor 2W-B i3 Series 2-wire, Photoelectric Smoke Detector, item 5 NEW System Sensor 2W-B 2WB i3 Series 2-Wire Photoelectric Smoke Detector Fire. List Price. A Installation of the 2W -B, 2WT -B, 4W -B, and 4WT -B detectors is simplified . PDF inSTaLLaTion and mainTenanCe inSTruCTionS Series Ensure proper wiring and power is applied. Enter a zip code, select a range, and choose a Distributor type to locate the nearest Distributor. System Sensor 2W-B Photoelectric i3 Smoke Detector, 2-Wire In Stock Other products from System Sensor System Sensor P4W-P Horn Strobe, White, Wall Mount, Four-Wire System Sensor PC2W Horn Strobe, White, Ceiling Mount, Two-Wire, FIRE Lettering System Sensor B210LP Detector Base, Plug-In RA400Z Remote Annunciator to be connected. Car & Truck Safety & Security Accessories. (See Figure 4.). Unlike traditional detection systems, Reflected Beam Smoke Detectors were designed for spacious rooms, open areas, and high ceilings; their innovative features make them popular choices for spaces like warehouses, atriums, arenas, and churches. AUX OR + For best system performance, all wiring should be installed in separate grounded conduit; do not mix fire alarm system wiring in the same conduit as any other electrical wiring. Will these cover up a low voltage mudring? Proper wire gauges should be used. Figure 4: Recessed Test Switch Opening and SENS-RDR Position Department, RA #__________, 3825 Ohio Avenue, St. Charles, IL 60174. Models 2W-B and 2WT-B also include an output that allows an optional Model RA400Z Remote Annunciator to be connected. With. models must be used with compatible UL Listed panels only. detector to finish the power-up cycle (see Table 2). If they are not just take a photo of the connections and land what is connected to the positive connection the new plates positive and same with the negative. be used in lieu of the tests specified under Testing. This includes cleaning, maintenance or screen replacement. =&5~9KY!m}oC%IF# V. into the base and lock into place with a click. For convenience, the 2W-B mounting base can also be directly mounted to the ceiling using drywall fasteners. The calculated illumination is required to be at least 0.0375 lumens/ft2 at any point within the covered area. 2W-B and 2WT-B, connect detectors only to compatible alarm control panels avg., 100 A peak, Operating Temperature Range: 32 to 120F (0 to 49C), Operating Humidity Range: 0% to 95% RH, noncondensing. 3. Access a cross-reference document that covers AV notification appliances, from the previous SpectrAlert Advance line to the latest L-Series line. from the mounting base without the use of a tool.